Check that a source is sending
This page explains how to check that a data source is sending events, what to look at when it is not, and how to read Pipeline Stats.
Role needed: a user with the Admin or Super Admin account type. A user with a custom role needs Settings access and, under Collection & Automation, Log Onboarding with Read to see source status. To open Pipeline Stats the role also needs Stats with Read.
Check the status of a source
- Select Settings, then Log Onboarding under Collection & Automation.
- Read the Status and EPS columns, or select a count in the strip at the top to filter by status.
The status is worked out each time the page loads, from the events stored in the last five minutes.
| Status | What it tells you |
|---|---|
| Active | An event arrived in the last five minutes. EPS shows the average events per second over that time. |
| No Data | Events arrived before but none in the last five minutes. A source that sends less than one event every five minutes shows No Data between events. |
| Pending | No event has ever been stored for the source. |
| Unknown | The console could not check. Reload the page. |
Check the events in Search
An Active status tells you events arrive. To see them, select Search in the navigation menu, set the time range to Last 15 Minutes, and run a query for the source:
| Source | Query |
|---|---|
| Syslog or Windows source matched by address | source=log_* | where host.ip = '192.0.2.10' |
| Syslog source matched by host name | source=log_* | where host.hostname = 'fw01' |
| NetFlow | source=log_* | where event.dataset = 'netflow' |
Open an event with the chevron at the start of its row and check that fields such as the user, addresses and action are filled. See Search events.
When a source stays Pending or turns to No Data
Work through the list for the kind of source.
Syslog
- Open Settings, Pipeline Stats, and read Rejected syslog senders. If the device's address is listed, the appliance sees the device under an address that does not match the source. A device behind address translation, or a relay, arrives from a different address. Correct the IP on the source, or use Hostname. A Reason of Source disabled means the source is disabled.
- Check that UDP port 514 is open from the device to the appliance. See Appliance requirements.
- Check the vendor and product. A wrong choice does not stop events being stored, but the fields are missing. See How events are parsed.
- If a Processing rule is set, check that it is not dropping the events. The Drop chart on Pipeline Stats counts them.
Database, SFTP and API sources
- Check that the appliance can reach the host and port of the source, for example through the firewall.
- Check the credential and, for a database, the query and Position Column. A query that already has its own
WHEREorORDER BYat the end fails. - Allow at least one Poll Interval (seconds). The default is 300.
- For an SFTP source, check that new file names sort after the previous ones. See Collect files from an SFTP server.
NetFlow
Search for events with the dataset netflow. See Collect NetFlow.
If the source still does not send after these checks, see Events are not arriving, which also lists what to collect before you contact support.
Read Pipeline Stats
Select Settings, then Pipeline Stats under Health & Diagnostics. Choose Last 30 minutes, Last 1 hour or Last 24 hours.
| Panel | Shows |
|---|---|
| General | Events stored over the period. |
| Drop | Events dropped by processing rules. |
| Persist | Stored events (Raw) and dropped events (Filtered). |
| Unknown sources | Syslog messages the appliance rejected, over the period. |
Below the panels, Rejected syslog senders lists each sender the appliance rejected, with its Reason, the Messages rejected and when it was Last seen. See Collect syslog.
Next steps
- Search events
- Create and edit a Detection Rule: detect activity in the events you now collect.
- Onboard a data source
- Collect syslog